SFM0442E

SMF recording: program1 passed program2 a storage_class@storage_location buffer with no GMT write TOD value

Explanation: This message is issued by the four SMF recording programs (see list under message SFM0435D) when a program determines that the write time-of-day has not been inserted in the SMF work buffer by the calling program prior to requesting a write-SMF-record function. In the message text:

program1 is the name of the calling program

program2 is one of the four programs that create VFTP SMF records

storage_class is the four character name of an SMF work buffer class

storage_location is the address of the buffer that was passed

The relationship of SMF work buffer classes to SMF subtypes and SMF recording programs is shown below.

Subtype Program2 Description
1 SFMCO030 Transfer
2 SFMCO031 Logon failure
3 SFMCO032 Request rejected by VFTP server exit
4 SFMCO033 Summary statistics

Action: Save the job log from the VFTP agent, any SVC dumps that were produced, and contact SDS Technical Support.