SMF recording: program1 passed program2 an invalid function code=function_number
Explanation: This message is issued by the four SMF recording programs (see list in message SFM0435D) when the calling program passes an invalid function request code. In the message text:
program1 is the calling program’s name
program2 is the name of the SMF recording program
function_number is the one byte hexadecimal code that was passed.
Function requests are represented by “one bits” in the low order 3 bits of the function byte: bit 0 = create, bit 1 = update, and bit 2 = write.
Depending on the SMF subtype being written, some functions can be combined in a single request.
Action: Save the job log from the VFTP agent, any SVC dumps that were produced, and contact SDS Technical Support.